Products>Combined Cycle>THERMOFLEX>Sample 1 Basic Rankine Cycles
This is a design point model of an elementary Rankine cycle without reheat or feedwater heating. Net power at design point is 110.1 MW with a 31.1% net LHV efficiency.
A non-reheat Rankine cycle with three Feedwater Heaters: One LP, an open heater
(Deaerator) and one HP. The LP heater is of the 'Pumped Forward' type, the
Deaerator is a 'Contact' heater, and the HP heater has a drain cooler before its
condensate is flashed back to the deaerator. This cycle uses thermodynamic
assumptions that are identical to the previous model; same throttle conditions,
same expansion efficiency, and the same condenser pressure, but includes
feedwater heating. Use of feedheating by steam turbine extraction reduces net
power output by 9.2 MW, but increases net electric efficiency by 2.4%. This
cycle makes 100.9 MW net output at 33.5% net LHV efficiency. |
|