Return Sample 1 Sample 2 Sample 3 Sample 4 Sample 5


Products>Combined Cycle>GT PRO>Sample 2

 

Combined Heat and Power (Cogeneration) Plant

Combined heat and power facility generates 28.7 MW of electric output and 53.3 MW of thermal output for a heat to power ratio of near 1.9.  Two gas turbines exhaust into fired two-pressure vertical waste heat boilers to make 78 tonne/hour superheated steam at 40 bar / 325 C and 3 tonne/hour saturated steam at 7bar.  Gas turbines use steam injection for NOx control, and use distillate as a backup fuel.  Plant net power is 28.7 MW at 79.8% CHP efficiency and 27.9% LHV net electric efficiency (12900 kJ/kWhr net LHV heat rate).  Total installed US plant costs range from 1057 to 1258 $/kW depending on location.

 


[Home] [Customer Support] [Products] [Events] [Representatives] [Download Catalog] [Request Free Trial]

Thermoflow, Inc.

29 Hudson Road · Sudbury, MA  01776 · USA · (P) +1 978-579-7999 · (F) +1 978-579-5995

info@thermoflow.com

Thermoflow Europe GmbH

Gartenstrasse 18, D-35469 Allendorf · GERMANY · (P) +49 640-790-6991 · (F) +49 640-790-6992

huschka@thermoflow.com